CloseX
Datexel

Dove siamo

Via Monte Nero 40b, Tradate (VA)

Telefono

(+39) 0331 841070

Contattaci

Where we are

Via Monte Nero 40b, Tradate (VA)

Phone

(+39) 0331 841070

Contact us
  • Company Profile
  • Products
    • Signal Transmitters And Converters
      • Signal Converters
      • Modbus RTU Converters
      • Isolators
      • Trip Amplifier
      • Loop Powered Transmitters
    • I/O Server Modules
      • Modbus RTU Protocol
      • Modbus TCP Protocol
      • CAN OPEN Protocol
      • Profinet IO Protocol
    • Gateway / Serial Interfaces
    • Client Server Unit
    • Display
    • Power Supplies
  • Software & Driver
  • Accessories
    • Configuration Interfaces And Cables
  • Certifications
  • Assistance
  • Distributors
    • Italy
    • World
  • Solution Provider
    • Italy
  • Contacts
IT en
  • IT
    Italiano
  • EN
    English
Datexel
IT en
  • IT
    Italiano
  • EN
    English

DAT8014

Home / Prodotti / DAT8014
DAT8014
DAT8014
Home / I/O Server Modules / Modbus TCP Protocol / DAT8014

DAT8014

Modbus TCP/IP server module with 4 isolated input channels for RTD, Resistance and Potentiometer

SKU:DAT8014_EN
Categories:
I/O Server Modules, Modbus TCP Protocol
Attention: the photo of the product may not correspond to reality.
During installation, always consult the datasheet.
Richiedi informazioniRequest more information
  • Description
  • Additional information
  • 3D view
  • Download

Product Description

The DAT8014 module is a Modbus TCP server unit that can convert up to 4 analog signals applied to the input in engineering units in digital format.
The inputs can be connected to sensors RTD or resistance to two or three wires.
The input channels are electrically isolated from each other.
The device guarantees high accuracy and a stable measure versus time and temperature. In order to ensure the safety plant, the device is provided with a Watch-Dog Timer system.The Ethernet interface allows reading and writing in real time the values of the internal registers of the device.
The LEDs of signalling of Ethernet activity and power supply allow a direct monitoring of the system functionality.
The built-in Web Server of DAT8014 allows the remote visualization, acquisition of the analog inputs and the access to the main Ethernet programming parameters. To find the devices and configure the network parameters, it is possible to use the “Search Device” software developed by DATEXEL.
The connection is made by removable screw-terminals (inputs and power supply) and RJ45 plug (Ethernet).
The device DAT8014 realizes a full electrical isolation between the lines, introducing a valid protection against the effects of all ground loops eventually existing in industrial applications. The device is housed in a rough self-extinguishing plastic enclosure which, thanks to its thin profile of 22.5 mm only, allows a high density mounting on EN-50022 standard DIN rail.

Additional information

Container Type

Vertical DIN Rail

Isolation

YES

Features

4 ISOLATED RTD, POTENTIOMETER INPUTS

Communication

Modbus TCP/IP

N° Analog Inputs

4

Analog Input Type

Potentiometer, Resistance, RTD (PT100, PT1K, NI100, NI1K)

3D view

Download

Documentation
View Data Sheet Guide
Certifications
Certification UL Certificate
Mechanical Drawings
File DWG

Richiedi informazioni

Compila il form con i dati richiesti, ti ricontatteremo entro 24 ore.

    Request more information

    Fill out the form with the requested data, we will contact you within 24 hours.

      Related products

    • DAT10016

      DAT10016

      Modbus RTU/ASCII device with 4 mV and Thermocouple input channels in 6 DIN module box

    • DAT10015

      DAT10015

      Modbus RTU/ASCII device with 4 Inputs ± 10 V + 4 Inputs ± 20 mA (passive) in 6 DIN module box

    • DAT10017-I

      DAT10017-I

      Modbus RTU/ASCII device with 8 Analog Inputs ± 20 mA (passive) in 6 DIN module box

    • DAT10019

      DAT10019

      Modbus RTU/ASCII device with 8 input channels for Resistance and RTD 2 wires in 6 DIN module box
    • DAT3016

      DAT3016

      Modbus RTU/ASCII device with 4 mV and Thermocouple input channels

    • DAT3140

      DAT3140

      Modbus RTU/ASCII device with 8 Digital Inputs and 8 Digital NPN Outputs

    • DAT7188

      DAT7188

      CANopen Slave module with 8 digital inputs and 8 digital PNP outputs

    • DAT10014

      DAT10014

      Modbus RTU/ASCII device with 4 RTD, Resistance and Potentiometer input channels in 6 DIN module box

    • DAT3188-8

      DAT3188-8

      Modbus RTU/ASCII device with 8 Digital Inputs and 8 Digital PNP Outputs

    • DAT3188-4

      DAT3188-4

      Modbus RTU/ASCII device with 4 Digital Inputs and 8 Digital PNP Outputs

    • DAT3015-V

      DAT3015-V

      Modbus RTU/ASCII device with 4 Analog Inputs ± 10 V

    • DAT3018

      DAT3018

      Modbus RTU/ASCII device with 8 mV and Thermocouple input channels

      • DAT4235
        Previous ProductDAT4235
      • Next ProductDAT4540/R
        DAT4235

      Contatti

      Via Monte Nero 40b, 21049 Tradate (VA)
      (+39) 0331 841070
      datexel@datexel.it

      Navigazione

      • Prodotti
      • Software & Driver
      • Accessori
      • Certificazioni

      Corporate

      • Azienda
      • Assistenza
      • Italia
      • Sede e Contatti

      News

      • Blog
      • Novità ed Eventi

      Contacts

      Via Monte Nero 40b, 21049 Tradate (VA)
      (+39) 0331 841070
      datexel@datexel.it

      Navigation

      • Products
      • Software & Driver
      • Accessories
      • Certifications

      Corporate

      • Company Profile
      • Assistance
      • Italy
      • Contacts

      News

      • Blog
      • News and Events
      © 2021-2025 Datexel S.r.l. • Via Monte Nero 40/b, 21049 Tradate • P.IVA IT02058840121 • Privacy Policy • Cookie Policy • Cookies Preferences • Web Agency: Gweb
      Generic selectors
      Exact matches only
      Search in title
      Search in content
      Post Type Selectors